PureWatts AI

    Solar energy assistant

    📍 Home

    Hi there! 👋

    I'm your PureWatts AI assistant. Ask me anything about solar energy, system sizing, or how to use the platform.

    Skip to content

    Cross River State

    Rooftop solar in Akamkpa, Cross River: what the roofs are worth

    Akamkpa has 39,726 buildings with a viable rooftop and 752k kWp of roof capacity. 97% run a generator, and together they spend ₦38.1bn a year on energy.

    Viable buildings

    39,726

    Usable roof area

    3.36m m²

    752k kWp roof capacity

    Energy spend

    ₦38.1bn/yr

    38.4m kWh/yr burned on generators

    Median payback

    1.9 yr

    Median IRR 59% (cash saved)

    The savings bracket for Akamkpa

    Approach B

    Cash saved

    What these buildings stop paying — merit order, capped at current spend.

    Current energy spend₦38.1bn/yr
    Year-one cash saved₦37.9bn
    Lifetime cash saved₦1.6tn
    NPV₦248bn
    Median IRR59%
    Median payback1.9 yr
    Unlocked energy36.5m kWh/yr
    Approach A

    Energy value (upper bracket)

    What the energy is worth if full latent demand were met. Not cash saved.

    Installed capacity199k kWp
    Capex₦183bn
    Year-one energy value₦163bn
    Lifetime energy value₦7.47tn
    NPV₦1.27tn
    Median IRR109%
    Median payback0.9 yr

    Three ways to size Akamkpa's rooftops

    Solar + battery. The default headline scenario, and the one the SEO fact base quotes. Prices the energy a full solar+storage system would deliver.

    Baseline: mixed
    Counterfactual: grid when available, generator otherwise, weighted by the NTL-derived grid availability. The realistic case, and what the headline numbers use. Always falls between grid and genset by construction.

    Read with care: Sized to LATENT demand — the energy the building would use if it could. Against a cash baseline that only reflects today's spend this looks oversized; that is what sc3 exists to fix.

    System size
    199k kWp
    Capital cost
    ₦183bn
    Year 1 savings
    ₦163bn/yr
    NPV
    ₦1.27tn
    Median IRR
    109%
    Median payback
    0.9 yr

    How many rooftops in Akamkpa actually pay

    Counted building by building on the cash-saved basis (merit-order sized, valued against what the building spends today), not read off an average. 39,726 of 39,726 clear a positive NPV.

    Payback

    Under 3 years35,894 (90%)
    Under 5 years38,369 (97%)
    Under 7 years39,726 (100%)
    Under 10 years39,726 (100%)

    Return (IRR)

    Above 10%39,726 (100%)
    Above 15%39,726 (100%)
    Above 20%38,404 (97%)
    Above 25%37,893 (95%)
    CO₂ avoided

    69.8m kg/yr

    Fuel avoided

    18.9m L/yr

    Energy unlocked

    36.5m kWh/yr

    Demand that is suppressed today

    People served

    178k

    What hardware costs right now

    Median advertised rates from our Nigerian market tracker — the same prices used to cost a system in Akamkpa.

    Solar panels

    250

    ₦/W

    Inverters

    127,419

    ₦/kVA

    Batteries

    177,500

    ₦/kWh

    Building mix in Akamkpa

    Load profile

    SegmentBuildings With generator Spend ₦/yr Cash saved yr 1 (B) Median IRR Median payback
    Residential35,73434,651₦22.1bn₦22bn59%1.9 yr
    Commercial General1,6841,559₦6.43bn₦6.43bn49%2.1 yr
    Commercial Retail805742₦172m₦172m51%2.1 yr
    Industrial709687₦1.43bn₦1.42bn55%1.9 yr
    Anchor409402₦7.51bn₦7.43bn63%1.6 yr
    Worship313311₦302m₦302m53%2.1 yr
    Filling Station3030₦39.1m₦39.1m53%1.9 yr
    Productive Use2323₦43.1m₦43.1m59%1.9 yr
    Hospitality1919₦86.9m₦86.9m57%1.9 yr

    Roof size band

    SegmentBuildings With generator Spend ₦/yr Cash saved yr 1 (B) Median IRR Median payback
    100 250m210,96810,669₦12.2bn₦12.1bn61%1.6 yr
    Under 30m210,1119,739₦591m₦585m57%1.9 yr
    50 100m29,5869,252₦2.66bn₦2.58bn57%1.9 yr
    30 50m26,1465,929₦679m₦679m57%1.9 yr
    250 1000m22,8342,758₦15.2bn₦15.1bn61%1.6 yr
    Over 1000m28177₦6.88bn₦6.88bn55%1.9 yr

    Settlement type

    SegmentBuildings With generator Spend ₦/yr Cash saved yr 1 (B) Median IRR Median payback
    Urban12,99212,380₦12.9bn₦12.9bn61%1.6 yr
    Unclassified9,1938,933₦7.09bn₦7.06bn53%1.9 yr
    Rural8,8478,655₦7.11bn₦7.08bn63%1.6 yr
    Dense Urban8,6948,456₦11bn₦10.9bn55%1.9 yr

    Lead segment

    SegmentBuildings With generator Spend ₦/yr Cash saved yr 1 (B) Median IRR Median payback
    Standard37,45636,300₦24bn₦23.9bn59%1.9 yr
    SME High1,1621,045₦5.34bn₦5.32bn53%2.1 yr
    Enterprise1,1081,079₦8.81bn₦8.74bn57%1.9 yr

    Demand tier

    SegmentBuildings With generator Spend ₦/yr Cash saved yr 1 (B) Median IRR Median payback
    3.012,23812,015₦23.5bn₦23.4bn
    0.010,1209,767₦438m₦438m
    2.010,1129,833₦4.98bn₦4.89bn
    1.04,8464,718₦726m₦722m
    4.01,9711,701₦4.87bn₦4.87bn
    5.0315267₦1.36bn₦1.36bn
    6.0124123₦2.23bn₦2.23bn

    Nearby LGAs in Cross River

    How these numbers are produced

    Approach A — energy value (upper bracket)

    Sizes the system to the building's full latent demand and values that energy at the mixed grid/generator tariff. It answers what the energy is worth — not what anyone currently pays.

    Approach B — cash saved (lower bracket)

    Sizes the system to demand that is actually served today, values it by merit order (solar displaces generator kWh first) and caps it at current spend. It answers what a building stops paying.

    Cohort: Viable rooftops (≥0.6 kWp potential).

    • Demand is modelled latent demand, not metered consumption.
    • Fuel is priced at ₦1,800/litre (operator-set). NBS reported ₦3,277/litre for May 2026 — on that basis every naira figure here is roughly 1.8× understated.
    • Generator ownership is a model output, not a survey result: it follows from the grid-availability scale and the 25% demand-suppression assumption.
    • Approach A prices energy nobody currently buys. Its savings must never be read as cash saved.
    • Demand is MODELLED LATENT demand, not metered consumption.
    • Generator ownership is model output, not survey.
    • Medians do not combine across groups — re-derive from the histograms.
    • Per-building files are float32 with 4 significant figures; cast to float64 before summing, because polars keeps Float32 sums in Float32.
    • Null scenario fields mean the roof cannot host 0.6 kWp, not zero savings.
    • `genset` was previously named `diesel` and now uses the segment's real fuel.
    • Ordering holds by construction: grid savings < mixed < genset.